Tellhow (Shenzhen) Electric Technologies Co., Ltd.
Chinese professional electrical equipments manufacturer

SIVACON 8PT Switchgears

By admin • Oct 11th, 2008 • Category: LV Switchgear Assemblies
1. General

SIVACON 8PT LV switchgear is promoted by SIEMENS in the middle of last 90’s. It’s highly reliable, flexible, economical & practical, safe and intelligentized, freshly showing in the electric distribution industry, broadly used for electric engineering, chemistry & petroleum, heavy industry and public facilities. TELLHOW has a long term cooperation of technology with SIEMENS, acquired the right to sell SIVACON 8PT and use this trademark. Germany SIEMENS provided completely technology data, workmanship and design software of this product to TELLHOW.

Product features:

  • The zinc-plated bones of SIVACON cubicle consists of each-bitted steel sheets, with precise size and stable structure.
  • Zinc-plated sheets ensure the performance of safe grounding and anticorrosion for long time; wearing plate and powder spraying coating prevent possible damage during the transportation, installation and running.
  • LV distribution equipment (TTA) type test was passed.
  • All withdrawable units available with standard operation interface.
  • It can communicate with profibus DP to become an intelligentized switchgear.
  • Apparatus compartment has a big size, suitable for the installation of various devices.
  • Modular functional unit can combine with lateral universal cabinet busbar freely and easy to install.
  • Circuit breaker can be drawer type or insert/pull-out type, easy to be replaced while the cubicle powers switch off.
  • Functional compartments can be parted to install additional components in necessary.
2. Normal Service Condition
  • The highest temperature of short time is : + 40℃ , 24 hours max average temperature is: + 35℃ ,
  • lowest temperature is -5℃ .
  • Working conditions of measuring instruments and protection relay should be conformed to the
  • manufacturer’s notes.
  • Set the weather condition by the regulation of IEC439-1, GB7251 for normal working. Ambient
  • relative humidity should be ≤50% at 40℃ .
  • Indoor installation condition of the switchgear should conform to standard requirements. Ventilation
  • or heating device should be equipped under the frost/dewdrop weather.
  • The switchgear should be run below its rated capacity under the condition of 1000m altitude and
  • above or that ambient temperature is higher than what stated as above.
3. Configuration
Apparatus Type Manufacturer
Circuit breaker 3WL、3VL、3WT、3VT SIEMENS
CT BH Shenzhen Xin’An Equipment
ALH Shanghai APT
Instrument PD194 SFERE Electric
PD800 Shanghai APT
Capacitor MPK EPCOS
BCMJ Shenzhen Kangtian Capacitor
Cubicle SIVACOM 8PT TELLHOW
4. Structure
  • Busbar compartment
  • Device compartment
  • Cable feeding compartment
  1. Main busbar
  2. Branch busbar
  3. Circuit breaker
  4. Control panel
5. Technical Parameters
Item Parameter
Rated voltage Rated insulation voltage AC 1000V
Rated running voltage Up to 690V
Rated frequency 50Hz
Main busbar rated current Max working current Up to 7400A
Rated peak withstand current Up to 375kA
Rated short time withstand current Up to 150kA,1S
Up to 120A ,3S
Vertical busbar rated current Vertical busbar max working current Up to 630A
Rated peak withstand current Up to 250kA
Rated short time withstand current Up to 65kA,1S
Up to 50A ,3S
Operation power Rated voltage AC 220V/AC 380V
Dimension (mm) (W) 600、800、1000、1200
(D) 600、800、1000、1200
(H) 2200
Standard IEC60439-1,DINEN60439-1,VDE0660, IEC61641
Protection class There’re holes in door and top for ventilation, protection class relates with different working area, can reach IP30/31or IP40/41 respectively; concerning the cubicle without ventilation, the protection class is IP54,while the cable is IP00 or IP40.

Related posts:

  1. MNS Switchgears 1. General THMNS LV withdrawable switchgear is developed and...
  2. GCK Switchgears 1. General THGCK, THGCL series of switchgears are combined...
  3. KYN28A-12/T1250-31.5 Switchgear 1. General Applicable for single busbar distribution sub-system, AC...
  4. TKYNH-12 Metalclad Switchgear 1. General Applicable for single busbar distribution sub-system, AC...
  5. XGN15-12 Metal-enclosed Switchgear 1. General Applicable for single busbar distribution sub-system, AC...

Related posts brought to you by Yet Another Related Posts Plugin.

Tagged as:

admin is
Email this author | All posts by admin

INQUIRY